ADAP-AEDM2D

ELECTRONIC SINGLE-PHASE DIRECT STARTER FOR TWO DREINAGE PUMP

 

 

Code Power at 230V Thermal Protection (A)
AEDM2D HP-0,5/3    KW-0,37/2,2  0,5 – 20

 

Topographic electronic card

Description

IP55, PVC plastic cabinet, dimensions 300x220x120mm
Door interlock switch-disconnector
Electronic card
Ammetric control with TA
230V/12V safety transformer for auxiliary circuit
Auxiliary circuit fuses
Man - 0 - aut modality
Exchanger (integrated)
Acoustic and visula alarm
Safety battery with battery change
Input of working level proble
Input of support level proble
Input of stop level proble
Input of too much full level proble
Input of too much low level proble
Terminal board and cable clamps
Voltage 230V (1P+N) 50 - 60 Hz
Certification and electric layout
User manual

Optionals

Ammeter
Voltmeter
N°2 auxiliary contacts for klixon

Techical date

Electronic control with micotrpocessor
Control of inputs with protection against electric and electrostatic discharge
Input tests (RL) and (LMIN) with warning leds
Alternating pumps with a delay between the start of the two pumps
AUT/OFF/RESET push buttons for thermal protection
Non volatile memory
Warning leds for power-in, running motors, alarm, resistive level relay, security probes, overload and automatic operating modality
Electronic setting of level relay sensibility (2 - 20 kohm)
Electronic control of maximum current by means of TA
Electronic control of maximum current by means of TA
Different electronic setting of current for both motors (1 - 22A)
Different electronic setting of stop delay timer for both motors (0 - 120 sec.)
Programmable start delay time for motor 2 (0 - 20 sec.)
Electronic setting of start delay time for overload current (0 - 10 sec.) for both motors
Setting of level relay in filling / emptying working modality
Setting of level relay delay (0,1 - 2 sec.)
Possibility of using normal thermal relays controlled by means of microprocessor
Output alarm with relay 12A - 250V NO/C/NC
Input for low voltage external pressure controllers or level probes(5V)
Lowest current on inputs (< di 0,5 mA)
Galvanically insulated input for level relay
No-bouncing inputs controlled by software
Setting of fast start / stop of the motors
Sequential start / stop of motors (low current of start)
Protection with fuses for both motors